An experimental analysis for the evaluation of adiabatic and overall effectiveness of an effusion cooling geometry is presented in this paper. Chosen configuration is a flat plate with 98 holes, with a feasible arrangement for a turbine endwall. Fifteen staggered rows with equal spanwise and streamwise pitches , a length to diameter ratio of 42.9 and an injection angle of 30 deg are investigated. Measurements have been done on two different test samples made both of plastic material and stainless steel. Adiabatic tests were carried out in order to obtain adiabatic effectiveness bidimensional maps. Even if a very low conductivity material polyvinyl chloride was used, adiabatic tests on a typical effusion geometry suffer, undoubtedly, from conductive phenomena: a full three-dimensional finite element method postprocessing procedure for gathered experimental data was therefore developed for reckoning thermal fluxes across the surface and then correctly obtaining adiabatic effectiveness distributions. The objective of the tests performed on the conductive plate, having the same flow parameters as the adiabatic ones, was the estimation of overall efficiency of the cooled region. Experimental measurements were carried out imposing two different crossflow Mach numbers, 0.15 and 0.40, and varying blowing ratio from 0.5 to 1.7; effectiveness of the cooled surface was evaluated with a steady-state technique, using thermochromic liquid crystal wide band formulation. Results show that the postprocessing procedure correctly succeeded in deducting undesired thermal fluxes across the plate in adiabatic effectiveness evaluation. The increasing blowing ratio effect leads to lower adiabatic effectiveness mean values, while it makes overall effectiveness to grow. Finally, Reynolds-averaged Navier–Stokes steady-state calculations were performed employing an open source computational fluid dynamics code: an adiabatic case has been simulated using both a standard and an anisotropic turbulence model. Numerical achievements have then been compared with experimental measurements.
Skip Nav Destination
e-mail: bruno.facchini@htc.de.unifi.it
e-mail: lorenzo.tarchi@htc.de.unifi.it
e-mail: lorenzo.toni@htc.de.unifi.it
e-mail: alberto.ceccherini@htc.de.unifi.it
Article navigation
October 2010
Research Papers
Adiabatic and Overall Effectiveness Measurements of an Effusion Cooling Array for Turbine Endwall Application
Bruno Facchini,
Bruno Facchini
Department of Energy Engineering “Sergio Stecco,”
e-mail: bruno.facchini@htc.de.unifi.it
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italy
Search for other works by this author on:
Lorenzo Tarchi,
Lorenzo Tarchi
Department of Energy Engineering “Sergio Stecco,”
e-mail: lorenzo.tarchi@htc.de.unifi.it
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italy
Search for other works by this author on:
Lorenzo Toni,
Lorenzo Toni
Department of Energy Engineering “Sergio Stecco,”
e-mail: lorenzo.toni@htc.de.unifi.it
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italy
Search for other works by this author on:
Alberto Ceccherini
Alberto Ceccherini
Department of Energy Engineering “Sergio Stecco,”
e-mail: alberto.ceccherini@htc.de.unifi.it
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italy
Search for other works by this author on:
Bruno Facchini
Department of Energy Engineering “Sergio Stecco,”
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italye-mail: bruno.facchini@htc.de.unifi.it
Lorenzo Tarchi
Department of Energy Engineering “Sergio Stecco,”
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italye-mail: lorenzo.tarchi@htc.de.unifi.it
Lorenzo Toni
Department of Energy Engineering “Sergio Stecco,”
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italye-mail: lorenzo.toni@htc.de.unifi.it
Alberto Ceccherini
Department of Energy Engineering “Sergio Stecco,”
University of Florence
, Via di Santa Marta 3, Firenze 50139, Italye-mail: alberto.ceccherini@htc.de.unifi.it
J. Turbomach. Oct 2010, 132(4): 041008 (11 pages)
Published Online: April 29, 2010
Article history
Received:
March 9, 2009
Revised:
May 6, 2009
Online:
April 29, 2010
Published:
April 29, 2010
Citation
Facchini, B., Tarchi, L., Toni, L., and Ceccherini, A. (April 29, 2010). "Adiabatic and Overall Effectiveness Measurements of an Effusion Cooling Array for Turbine Endwall Application." ASME. J. Turbomach. October 2010; 132(4): 041008. https://doi.org/10.1115/1.3213555
Download citation file:
Get Email Alerts
Related Articles
A Novel Technique for Assessing Turbine Cooling System Performance
J. Turbomach (July,2011)
Leading-Edge Film-Cooling Physics—Part III: Diffused Hole Effectiveness
J. Turbomach (April,2003)
Effect of Film Cooling on Turbine Capacity
J. Eng. Gas Turbines Power (January,2010)
Inverse Design of and Experimental Measurements in a Double-Passage Transonic Turbine Cascade Model
J. Turbomach (July,2005)
Related Proceedings Papers
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Approximate Analysis of Plates