Solar air heaters (SAHs) are the simplest form of nonconcentrating thermal collectors. SAHs utilize solar thermal energy to increase the temperature of air for thermal applications of less than 80 °C. The energy efficiency of SAHs is significantly low due to poor convective heat transfer between the absorber and the air medium. In this present study, it is aimed to increase the convective heat transfer by modifying the absorber and the type of air flow inside the duct. Experimental studies were performed to study about the energy and exergy efficiencies of SAH with the absorber of longitudinal circular fins. The thermal analysis of the SAH is evaluated for five mass flow rates of 30, 45, 60, 75, and 90 kg/h m2 flowing inside the duct of thickness 100 mm. The impact of the flow rate on the absorber and air temperature, temperature difference (ΔT), energy and exergy efficiencies, irreversibility, improvement potential, sustainability, and CO2 reduction potential is studied. The experimental results show that the first and second laws of thermodynamic efficiency increase from 44.13% to 56.98% and from 24.98% to 36.62% by increasing the flow rate from 30 to 90 kg/h m2. The results conclude that the air flow duration inside the duct plays an important role in efficiency of the solar air heater. Therefore, lower flow rate is preferred to achieve maximum outlet air temperature and temperature difference.

References

1.
Prasad
,
B. N.
, and
Saini
,
J. S.
,
1988
, “
Effect of Artificial Roughness on Heat Transfer and Friction Factor in a Solar Air Heater
,”
Sol. Energy
,
41
(
6
), pp.
555
560
.
2.
Bayrak
,
F.
,
Oztop
,
H. F.
, and
Hepbasli
,
A.
,
2013
, “
Energy and Exergy Analyses of Porous Baffles Inserted Solar Air Heaters for Building Applications
,”
Energy Build.
,
57
, pp.
338
345
.
3.
Oztop
,
H. F.
,
Bayrak
,
F.
, and
Hepbasli
,
A.
,
2013
, “
Energetic and Exergetic Aspects of Solar Air Heating (Solar Collector) Systems
,”
Renew. Sustain. Energy Rev.
,
21
, pp.
59
83
.
4.
Hepbasli
,
A.
, and
Akdemir
,
O.
,
2004
, “
Energy and Exergy Analysis of a Ground Source (Geothermal) Heat Pump System
,”
Energy Convers. Manage.
,
45
(
5
), pp.
737
753
.
5.
Chandra
,
R.
, and
Sodha
,
M. S.
,
1991
, “
Testing Procedures for Solar Air Heaters: A Review
,”
Energy Convers. Manage.
,
32
(
1
), pp.
11
33
.
6.
Moummi
,
N.
,
Chabane
,
F.
,
Benramache
,
S.
, and
Brima
,
A.
,
2013
, “
Thermal Efficiency Analysis of a Single-Flow Solar Air Heater With Different Mass Flow Rates in a Smooth Plate
,”
Front. Heat Mass Transfer
,
4
(
1
), pp.
1
6
.
7.
Pakdaman
,
M. F.
,
Lashkari
,
A.
,
Tabrizi
,
H. B.
, and
Hosseini
,
R.
,
2011
, “
Performance Evaluation of a Natural-Convection Solar Air-Heater With a Rectangular-Finned Absorber Plate
,”
Energy Convers. Manage.
,
52
(
2
), pp.
1215
1225
.
8.
Alta
,
D.
,
Bilgili
,
E.
,
Ertekin
,
C.
, and
Yaldiz
,
O.
,
2010
, “
Experimental Investigation of Three Different Solar Air Heaters: Energy and Exergy Analyses
,”
Appl. Energy
,
87
(
10
), pp.
2953
2973
.
9.
Benli
,
H.
,
2013
, “
Experimentally Derived Efficiency and Exergy Analysis of a New Solar Air Heater Having Different Surface Shapes
,”
Renew. Energy
,
50
, pp.
58
67
.
10.
Akpinar
,
E. K.
, and
Koçyiğit
,
F.
,
2010
, “
Energy and Exergy Analysis of a New Flat-Plate Solar Air Heater Having Different Obstacles on Absorber Plates
,”
Appl. Energy
,
87
(
11
), pp.
3438
3450
.
11.
Karsli
,
S.
,
2007
, “
Performance Analysis of New-Design Solar Air Collectors for Drying Applications
,”
Renew. Energy
,
32
(
10
), pp.
1645
1660
.
12.
Kurtbas
,
I.
, and
Durmuş
,
A.
,
2004
, “
Efficiency and Exergy Analysis of a New Solar Air Heater
,”
Renew. Energy
,
29
(
9
), pp.
1489
1501
.
13.
Kabeel
,
A. E.
,
Hamed
,
M. H.
,
Omara
,
Z. M.
, and
Kandeal
,
A. W.
,
2018
, “
Influence of Fin Height on the Performance of a Glazed and Bladed Entrance Single-Pass Solar Air Heater
,”
Sol. Energy
,
162
, pp.
410
419
.
14.
Gao
,
W.
,
Lin
,
W.
,
Liu
,
T.
, and
Xia
,
C.
,
2007
, “
Analytical and Experimental Studies on the Thermal Performance of Cross-Corrugated and Flat-Plate Solar Air Heaters
,”
Appl. Energy
,
84
(
4
), pp.
425
441
.
15.
Cuzminschi
,
M.
,
Gherasim
,
R.
,
Girleanu
,
V.
,
Zubarev
,
A.
, and
Stamatin
,
I.
,
2018
, “
Innovative Thermo-Solar Air Heater, Energy and Buildings
,”
Energy Build.
,
158
, pp.
964
970
.
16.
Omojaro
,
A. P.
, and
Aldabbagh
,
L. B. Y.
,
2010
, “
Experimental Performance of Single and Double Pass Solar Air Heater With Fins and Steel Wire Mesh as Absorber
,”
Appl. Energy
,
87
(
12
), pp.
3759
3765
.
17.
El-Sebaii
,
A. A.
,
Aboul-Enein
,
S.
,
Ramadan
,
M. R. I.
,
Shalaby
,
S. M.
, and
Moharram
,
B. M.
,
2011
, “
Thermal Performance Investigation of Double Pass-Finned Plate Solar Air Heater
,”
Appl. Energy
,
88
(
5
), pp.
1727
1739
.
18.
Chaichan
,
M. T.
,
Ali
,
A. J.
, and
Abass
,
K. I.
,
2018
, “
Experimental Study on Solar Air Heating
,”
Al-Khwarizmi Eng. J.
,
14
(
1
), pp.
1
9
.
19.
Esen
,
H.
,
2008
, “
Experimental Energy and Exergy Analysis of a Double-Flow Solar Air Heater Having Different Obstacles on Absorber Plates
,”
Build. Environ.
,
43
(
6
), pp.
1046
1054
.
20.
El-Sawi
,
A. M.
,
Wifi
,
A. S.
,
Younan
,
M. Y.
,
Elsayed
,
E. A.
, and
Basily
,
B. B.
,
2010
, “
Application of Folded Sheet Metal in Flat Bed Solar Air Collectors
,”
Appl. Therm. Eng.
,
30
(
8–9
), pp.
864
871
.
21.
Kilkis
,
B.
,
2011
, “
Role of Radiant Panel Heating and Cooling in Net Zero Energy Buildings
,”
ASHRAE Trans.
,
117
(
1
).
22.
Altfeld
,
K.
,
Leiner
,
W.
, and
Fiebig
,
M.
,
1988
, “
Second Law Optimization of Flat-Plate Solar Air Heaters Part I: The Concept of Net Exergy Flow and the Modeling of Solar Air Heaters
,”
Sol. Energy
,
41
(
2
), pp.
127
132
.
23.
Altfeld
,
K.
,
Leiner
,
W.
, and
Fiebig
,
M.
,
1988
, “
Second Law Optimization of Flat-Plate Solar Air Heaters. Part 2: Results of Optimization and Analysis of Sensibility to Variations of Operating Conditions
,”
Sol. Energy
,
41
(
4
), pp.
309
317
.
You do not currently have access to this content.