Distributed generation (DG) using a parallel battery pack with photovoltaic (PV) system has been presented in this brief. Considering a two level inverter and a three phase transformer, a local load will be supplied by the DG and connected to a power grid. The DG has been connected to the high voltage network via a filter and a distribution power station. A nero-fuzzy network has been designed for the estimation of maximum power ability of PV and the connected dc/dc converter has been controlled relatively. So, the power management between the PV system and the battery pack can be confirmed. On the other hand, another controller has been designed for control of transferred power between the power network and the DG system that can control the battery pack power indirectly. Finally, a series of simulation results show the effectiveness of proposed method for some various conditions.

References

1.
Nigm
,
K.
, and
Hegazy
,
Y.
,
2003
, “
Intention Islanding of Distributed Generation for Reliability Enhancement
,”
IEEE Power Engineering Society General Meeting
(
PES 2003
), Toronto, Canada, July 13–17, pp.
208
213
.10.1109/PES.2003.1271025
2.
Pilo
,
F.
,
Celli
,
G.
, and
Mocci
,
S.
,
2004
, “
Improvement of Reliability in Active Networks With Intentional Islanding
,”
IEEE International Conference on Electric Utility Deregulation, Restructuring, and Power Technologies
(
DRPT 2004
), Hong Kong, April 5–8, pp.
474
479
.10.1109/DRPT.2004.1338023
3.
ZeinElDin
,
H. H.
,
Bhattacharya
,
K.
,
El-Saadany
,
E. F.
, and
Salama
,
M. M. A.
,
2006
, “
Impact of Intentional Islanding of Distributed Generation on Electricity Market Prices
,”
IEE Proc.: Gener., Transm. Distrib.
,
153
(
2
), pp.
147
154
.10.1049/ip-gtd:20045117
4.
IEEE Std. 929-2000
,
2000
, “
IEEE
Recommended Practice for Utility Interface of Photovoltaic (PV) Systems
.”10.1109/IEEESTD.2000.91304
5.
IEEE Std. 1547-2003
,
2003
, “
IEEE
Standard for Interconnecting Distributed Resources With Electric Power Systems
.” 10.1109/IEEESTD.2008.4816078
6.
Barsali
,
S.
,
Ceraolo
,
M.
,
Pelachi
,
P.
, and
Poli
,
D.
,
2002
, “
Control Techniques of Dispersed Generators to Improve the Continuity of Electricity Supply
,”
IEEE Power Engineering Society Winter Meeting
, New York, January 27–31, pp.
789
794
.
10.1109/PESW.2002.985115
7.
Liang
,
J.
,
Green
,
T. C.
,
Weiss
,
G.
, and
Zhong
,
Q.
,
2003
, “
Hybrid Control of Multiple Inverters in an Island-Mode Distribution System
,”
IEEE 34th Annual Conference on Power Electronics Specialist
(
PESC’03
), Acapulco, Mexico, June 15–19, pp.
61
66
.10.1109/PESC.2003.1218274
8.
Marei
,
M. I.
,
El-Saadany
,
E. F.
, and
Salama
,
M. M. F.
,
2004
, “
A Novel Control Algorithm for the DG Interface to Mitigate Power Quality Problems
,”
IEEE Trans. Power Deliv.
,
19
(
3
), pp.
1384
1392
.10.1109/TPWRD.2004.829922
9.
Zeineldin
,
H.
,
Marei
,
M. I.
,
El-Saadany
,
E.
, and
Salama
,
M. M. A.
,
2004
, “
Safe Controlled Islanding of Inverter Based Distributed Generation
,”
IEEE Power Engineering Specialist Conference
(
PESC’04
), Aachen, Germany, June 20–25.10.1109/PESC.2004.1355224
10.
Li
,
Y.
,
Vilathgamuwa
,
D. M.
, and
Loh
,
P.
,
2004
, “
Design, Analysis and Real Time Testing of a Controller for Multibus Microgrid System
,”
IEEE Trans. Power Electron.
,
19
, pp.
1195
1204
.10.1109/TPEL.2004.833456
11.
Tsai
,
H.-L.
,
Tu
,
C.-S.
, and
Su
,
Y.-J.
,
2008
, “
Development of Generalized Photovoltaic Model Using MATLAB/SIMULINK
,”
Proceedings of the World Congress on Engineering and Computer Science (WCECS 2008), San Francisco, October 22–24
.
12.
matlab Software Guide, Version
2010
,
Power System Toolbox
,
Electrical Sources Part, The MathWorks Inc., Natick, MA.
13.
Naderi
,
P.
, and
Farhadi
,
A.
,
2012
, “
Non-Driven Wheels Application for Intelligent Multi-Objective Control of Hybrid Vehicles
,”
Int. J. Rob. Control
,
27
(
2
), pp.
185
197
.10.2316/Journal.206.2012.2.206-3477
14.
Naderi
,
P.
, and
Mohammadi
,
T.
,
2011
, “
Distributed Generation, Using Battery Pack and Fuzzy Controller for Charge/Discharge Control
,”
J. Power Energy Syst.
,
5
(
3
), pp.
330
342
.10.1299/jpes.5.330
You do not currently have access to this content.