1-20 of 21
Keywords: Orthopedic devices
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Article Type: Expert View
J. Med. Devices. September 2018, 12(3): 034701.
Paper No: MED-18-1024
Published Online: July 13, 2018
.... Manuscript received February 6, 2018; final manuscript received May 23, 2018; published online July 13, 2018. Assoc. Editor: Michael Eggen. 06 02 2018 23 05 2018 Cardiovascular devices Medical devices Medical devices Neurological devices Orthopedic devices Rehabilitation devices...
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2018, 12(1): 011004.
Paper No: MED-17-1209
Published Online: November 22, 2017
... manuscript received October 9, 2017; published online November 22, 2017. Assoc. Editor: Rita M. Patterson. 26 04 2017 09 10 2017 Medical devices Medical devices Medical devices Orthopedic devices Sports Instrumentation and Devices Tissue engineered devices Design processes...
Journal Articles
Article Type: Design Innovation Paper
J. Med. Devices. March 2018, 12(1): 015001.
Paper No: MED-16-1357
Published Online: November 22, 2017
... received November 8, 2016; final manuscript received October 16, 2017; published online November 22, 2017. Assoc. Editor: Elizabeth Hsiao-Wecksler. 08 11 2016 16 10 2017 Medical devices Orthopedic devices Equipment Osteoarthritis is a common joint disease that results...
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2017, 11(4): 041005.
Paper No: MED-17-1205
Published Online: September 22, 2017
.... 14 04 2017 22 06 2017 Medical devices Orthopedic devices Design processes The large majority of total knees used today are of two types: posterior cruciate preserving with relatively shallow tibial bearing surfaces (cruciate retaining (CR) type) and cruciate substituting (PS...
Topics: Design, Knee
Journal Articles
Article Type: Design Innovation Paper
J. Med. Devices. December 2017, 11(4): 045001.
Paper No: MED-17-1193
Published Online: August 16, 2017
.... , 2015 , “ An Adjustable-Length Intramedullary Nail: Development and Mechanical Evaluation in Cervine Tibiae ,” ASME J. Med. Devices , 9 ( 2 ), p. 024503 . 10.1115/1.4030152 [8] Kuxhaus , L. , and Clark , A. M. , 2015 , “ Adjustable Length Orthopedic Device ,” Clarkson University...
Journal Articles
Article Type: Research-Article
J. Med. Devices. September 2017, 11(3): 031008.
Paper No: MED-16-1320
Published Online: June 27, 2017
...-wire of PR 60 after torsion test up to failure Manuscript received September 15, 2016; final manuscript received April 7, 2017; published online June 27, 2017. Assoc. Editor: Chris Rylander. 15 09 2016 07 04 2017 Medical devices Minimally invasive devices Orthopedic...
Journal Articles
Article Type: Research-Article
J. Med. Devices. September 2017, 11(3): 031004.
Paper No: MED-16-1225
Published Online: June 27, 2017
..., 2016; final manuscript received February 14, 2017; published online June 27, 2017. Assoc. Editor: Chris Rylander. 23 05 2016 14 02 2017 Medical devices Orthopedic devices Design processes With the aging of the population and the increasing traffic accidents, there has...
Topics: Bone, Deformation
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2017, 11(1): 011004.
Paper No: MED-16-1038
Published Online: December 21, 2016
... received February 17, 2016; final manuscript received October 17, 2016; published online December 21, 2016. Assoc. Editor: Rita M. Patterson. 17 02 2016 17 10 2016 Medical devices Medical devices Minimally invasive devices Orthopedic devices Design processes Equipment...
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2017, 11(1): 011006.
Paper No: MED-16-1236
Published Online: December 21, 2016
... 8, 2016; final manuscript received October 16, 2016; published online December 21, 2016. Assoc. Editor: Rita M. Patterson. 08 06 2016 16 10 2016 Medical robotics Orthopedic devices Robotic surgical systems have been used in total hip surgery for over 20 years...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2016, 10(4): 044509.
Paper No: MED-16-1201
Published Online: September 12, 2016
...: Venketesh Dubey. 29 03 2016 06 07 2016 Human factors Human performance and force assessment Medical devices Medical robotics Orthopedic devices Rehabilitation devices Design processes Duchenne muscular dystrophy (DMD) is the most common form of muscular dystrophy...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. June 2016, 10(2): 024502.
Paper No: MED-15-1242
Published Online: May 12, 2016
... generated in autocad . The symmetric resection plane was determined by fitting a plane to the central portion of the anterior surface, 15 mm in from the edge. Orthopedic devices A standard part of total knee arthroplasty (TKA) is to resect the articulating surface of the kneecap (patella...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. March 2016, 10(1): 014502.
Paper No: MED-15-1232
Published Online: January 12, 2016
.... Patterson. 28 07 2015 10 11 2015 Human factors Medical devices Medical devices Orthopedic devices Manufacturing processes Equipment In vivo wear of polyethylene hip bearings is an important metric for evaluating the clinical performance of these prostheses. Current...
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2016, 10(1): 011002.
Paper No: MED-15-1150
Published Online: November 16, 2015
... March 23, 2015; final manuscript received September 14, 2015; published online November 16, 2015. Assoc. Editor: Carl Nelson. 23 03 2015 14 09 2015 Human performance Force assessment Medical robotics Orthopedic devices Lower back pain is a prevalent health issue...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2015, 9(4): 044506.
Paper No: MED-15-1020
Published Online: August 12, 2015
.... 30 01 2015 13 07 2015 Orthopedic devices Plain standing X-ray images are widely used to evaluate foot disorders such as pes planus. This is because foot alignment changes with loading, and it is important to understand bone dynamics under this condition. However, the bones...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2015, 9(4): 044504.
Paper No: MED-15-1003
Published Online: August 6, 2015
... represent the initiation of the electric system and walking, respectively), and ( c ) in vivo walking of a transfemoral prosthesis user with a commercial electric pump (Ohio WillowWood LimbLogic) and the hybrid pump Orthopedic devices Rehabilitation devices Prosthetic sockets are secured...
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2015, 9(4): 041010.
Paper No: MED-15-1032
Published Online: August 6, 2015
... manuscript received March 23, 2015; published online August 6, 2015. Editor: Gerald E. Miller. 28 02 2015 23 03 2015 Medical devices Medical robotics Orthopedic devices Rehabilitation devices Equipment The capacity to navigate through the world creates opportunities...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. June 2015, 9(2): 024503.
Paper No: MED-14-1195
Published Online: June 1, 2015
... be sufficient for clinical use. Medical devices Orthopedic devices Design processes There were several limitations to this study, including small sample size. For machining ease, the prototypes were made of medical stainless steel, rather than the titanium alloy (Ti4Al6V) that is most commonly...
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2015, 9(1): 011010.
Paper No: MED-14-1189
Published Online: March 1, 2015
... utilizing older generation C-arms to minimize radiation scatter to practitioner. Medical devices Orthopedic devices Equipment Since the 1980s C-arm fluoroscopy has allowed orthopedic surgeons to perform certain procedures with minimal dissection and improved accuracy [ 1–3 ]. As minimally...
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2015, 9(1): 011006.
Paper No: MED-14-1198
Published Online: March 1, 2015
... were used to compare measured implant positioning versus the preprocedural template. Implanted component accuracy ranged from 1 deg–12 deg. Medical devices Medical instrumentation Orthopedic devices Equipment THA is one of the most frequent joint replacements (270,000 per year...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2014, 8(4): 044508.
Paper No: MED-14-1178
Published Online: October 14, 2014
... for decision making on fixation strategies appropriate to the area of bone treated. Medical devices Orthopedic devices Equipment Biomechanical and cellular defects associated with osteoporosis lead to structural changes in bone, which affect fracture pattern and fracture fixation [ 1...