1-20 of 367
Keywords: finite element analysis
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Article Type: Research-Article
J Biomech Eng. January 2023, 145(1): 011011.
Paper No: BIO-22-1130
Published Online: August 19, 2022
... design finite element analysis bone/implant contact initial stability, additive manufacturing Department of Biotechnology , Ministry of Science and Technology 10.13039/501100001407 DBTO0455 Department of Science and Technology, Ministry of Science and Technology 10.13039...
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. January 2023, 145(1): 014502.
Paper No: BIO-22-1008
Published Online: August 19, 2022
...@emails.bjut.edu.cn 1 Corresponding author. e-mail:  haisheng.yang@bjut.edu.cn 11 01 2022 14 07 2022 19 08 2022 pedicle screw spine vertebrae screw loosening simulated threaded screw screw parameters finite element analysis Beijing Municipal Education Commission 10.13039...
Topics: Screws, Thread
Journal Articles
Article Type: Research-Article
J Biomech Eng. December 2022, 144(12): 121003.
Paper No: BIO-22-1105
Published Online: August 19, 2022
...] Ben’ıtez , J. M. , and Montáns , F. J. , 2017 , “ The Mechanical Behavior of Skin: Structures and Models for the Finite Element Analysis ,” Comput. Struct. , 190 , pp. 75 – 107 . 10.1016/j.compstruc.2017.05.003 [8] Weickenmeier , J. , Jabareen , M. , and Mazza , E...
Includes: Supplementary data
Journal Articles
Article Type: Research-Article
J Biomech Eng. October 2022, 144(10): 101011.
Paper No: BIO-21-1461
Published Online: May 27, 2022
... BCC Porous Cell Structure and Their Association With Structure Porosity: A Combined Finite Element Analysis and Analytical Approach for Orthopedic Application ,” Proc. Inst. Mech. Eng. Part H J. Eng. Med. , 235 ( 7 ), pp. 827 – 837 . 10.1177/09544119211011309 [27] Talukdar , R. G...
Journal Articles
Article Type: Research-Article
J Biomech Eng. September 2022, 144(9): 091006.
Paper No: BIO-21-1387
Published Online: March 30, 2022
...-mail:  mohammed.ali@h-eng.helwan.edu.eg 02 11 2021 22 02 2022 30 03 2022 abdominal aortic aneurysm hemodynamics computational fluid dynamics COMSOL multiphysics finite element analysis References [1] Virani , S. S. , Alonso , A. , Aparicio , H. J...
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. May 2022, 144(5): 054502.
Paper No: BIO-21-1305
Published Online: January 21, 2022
... contribution is the theoretical development of the maximum static stress calculation for 12 different femoral stem models with the beam theory, followed by the comparison with the static finite element analysis (FEA) simulations and finally the experimental corroboration of one femoral stem model measuring...
Topics: Stress
Journal Articles
Article Type: Research-Article
J Biomech Eng. May 2022, 144(5): 051011.
Paper No: BIO-21-1235
Published Online: January 21, 2022
... foundation contact model finite element analysis knee joint secondary kinematics muscle forces Japan Society for the Promotion of Science 10.13039/501100001691 Grant-in-Aid for Scientific Research (B) 19H03970 Musculoskeletal (MS) modeling has been widely used as a noninvasive...
Journal Articles
Article Type: Research-Article
J Biomech Eng. July 2021, 143(7): 071005.
Paper No: BIO-20-1398
Published Online: April 2, 2021
.... , Seral , B. , Seral , F. , Palanca , D. , and Gracia , L. , 2000 , “ Three-Dimensional Finite Element Analysis of Several Internal and External Pelvis Fixations ,” ASME J. Biomech. Eng. , 122 ( 5 ), pp. 516 – 522 . 10.1115/1.1289995 [7] Goel , V. K...
Journal Articles
Article Type: Research-Article
J Biomech Eng. October 2020, 142(10): 101006.
Paper No: BIO-19-1456
Published Online: July 17, 2020
...@ucalgary.ca e-mail:  skucuk@kocaeli.edu.tr e-mail:  kayamemis@kocaeli.edu.tr 07 10 2019 13 05 2020 17 07 2020 finite element analysis knee joint mechanics creep fluid pressure meniscectomy meniscal lesion The meniscal tears are approximately 30% of possible tears...
Journal Articles
Article Type: Research-Article
J Biomech Eng. October 2020, 142(10): 101002.
Paper No: BIO-19-1350
Published Online: July 8, 2020
... finite element analysis implant hollowness and stiffness total hip replacement The failure of total hip joint replacement (THR) due to the effect of stress shielding has been well documented [ 1 – 3 ]. Incorporation of synthetic biomaterial (i.e., implant) forms new interface with the bone...
Includes: Supplementary data
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. August 2020, 142(8): 084502.
Paper No: BIO-19-1183
Published Online: April 8, 2020
.... Biomech. , 40 ( 2 ), pp. 271 – 280 . 10.1016/j.jbiomech.2006.01.007 [12] Gardiner , J. C. , and Weiss , J. A. , 2003 , “ Subject-Specific Finite Element Analysis of the Human Medial Collateral Ligament During Valgus Knee Loading ,” J. Orthop. Res. , 21 ( 6 ), pp. 1098 – 1106...
Includes: Supplementary data
Journal Articles
Article Type: Research-Article
J Biomech Eng. August 2020, 142(8): 081005.
Paper No: BIO-19-1406
Published Online: March 27, 2020
.... It is not thoroughly understood which screws and screw combinations play the most critical roles in fixation stability. This study conducted a detailed finite element analysis to evaluate critical parameters associated with screw cut-out failure. Several clinically relevant screw configurations and fracture gap sizes...
Includes: Supplementary data
Journal Articles
Article Type: Research-Article
J Biomech Eng. May 2020, 142(5): 051012.
Paper No: BIO-19-1293
Published Online: January 20, 2020
... underexpansion finite element analysis percutaneous coronary intervention Severe calcification is a great concern when implementing a stenting intervention. Stenting outcomes are affected by heterogeneous material properties of the plaque, which is composed by the dense calcification, lipid pool...
Journal Articles
Article Type: Research-Article
J Biomech Eng. April 2020, 142(4): 041006.
Paper No: BIO-19-1191
Published Online: December 12, 2019
...] Zhou , C. , and Willing , R. , 2019 , “ Development of a Biconcave Mobile-Bearing Lumbar Total Disc Arthroplasty Concept Using Finite Element Analysis and Design Optimization ,” J. Orthop. Res. , 37 (8), pp. 1805 – 1816 . 10.1002/jor.24315 [19] Rundell , S. A. , Day , J...
Includes: Supplementary data
Journal Articles
Article Type: Research-Article
J Biomech Eng. September 2019, 141(9): 091014.
Paper No: BIO-19-1120
Published Online: August 2, 2019
... finite element analysis cardiac fung strain energy function Trabeculae carneae are irregular muscular bundles that cover both ventricles and, along with papillary muscles, account for a significant proportion of ventricular mass (12–17%) [ 1 , 2 ]. They are arranged in a complex network...
Journal Articles
Article Type: Research-Article
J Biomech Eng. October 2019, 141(10): 101003.
Paper No: BIO-18-1127
Published Online: July 11, 2019
... 2018 06 06 2019 shoulder glenoid Hill–Sachs lesion finite element analysis fracture risk The introduction of arthroscopy in shoulder surgery has led to the development of the suture anchor in order to simplify the Bankart repair. Concern has been expressed following a few recent...
Journal Articles
Article Type: Research-Article
J Biomech Eng. July 2019, 141(7): 071002.
Paper No: BIO-18-1516
Published Online: June 5, 2019
...Ahmet Erdemir; Thor F. Besier; Jason P. Halloran; Carl W. Imhauser; Peter J. Laz; Tina M. Morrison; Kevin B. Shelburne Recent explorations of knee biomechanics have benefited from computational modeling, specifically leveraging advancements in finite element analysis and rigid body dynamics...
Journal Articles
Article Type: Research-Article
J Biomech Eng. June 2019, 141(6): 061004–061004-12.
Paper No: BIO-18-1434
Published Online: April 22, 2019
... design developed by optimizing performance in accelerated wear testing and in vitro flow studies. Finite element analysis models were created using abaqus . Meshing generated 246,225 nodes and 209,220 C3D8R elements with a thickness of five elements. Three leaflets were assembled with 120 deg rotation...
Includes: Supplementary data
Journal Articles
Article Type: Research-Article
J Biomech Eng. May 2019, 141(5): 051007.
Paper No: BIO-18-1350
Published Online: March 25, 2019
.... finite element analysis computational design nerve guidance conduits tissue engineering Nerve guidance conduits (NGCs) are tubular tissue engineering (TE) scaffolds used for nerve tissue repair. Specifically, NGCs (1) direct sprouting axons between nerve stumps, (2) concentrate neurotrophic...
Journal Articles
Article Type: Technical Briefs
J Biomech Eng. March 2015, 137(3): 034502.
Paper No: BIO-14-1136
Published Online: March 1, 2015
... and, further with remodeling, the chances of interface debonding increased only marginally. total hip arthroplasty finite element analysis bone remodeling interface failure genetic algorithms shape optimization multi-objective The adverse effects of implant-induced bone resorption...