Skip Nav Destination
Issues
February 2004
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Technical Papers
Modal Damping for Monitoring Bone Integrity and Osteoporosis
Sofia D. Panteliou, Agathi L. Xirafaki, Elias Panagiotopoulos, John N. Varakis, Nikos V. Vagenas, Christos G. Kontoyannis
J Biomech Eng. February 2004, 126(1): 1–5.
doi: https://doi.org/10.1115/1.1644561
The Influence of the Fixed Negative Charges on Mechanical and Electrical Behaviors of Articular Cartilage Under Unconfined Compression
J Biomech Eng. February 2004, 126(1): 6–16.
doi: https://doi.org/10.1115/1.1644562
Topics:
Biological tissues
,
Cartilage
,
Compression
,
Poisson ratio
,
Young's modulus
,
Electric potential
,
Pressure
,
Stress
,
Displacement
,
Equilibrium (Physics)
Modes and Balance of Energy in the Piezoelectric Cochlear Outer Hair Cell Wall
J Biomech Eng. February 2004, 126(1): 17–25.
doi: https://doi.org/10.1115/1.1644564
Topics:
Capacitance
,
Electric fields
,
Energy budget (Physics)
,
Membranes
,
Motors
,
Piezoelectric actuators
,
Pressure
,
Stiffness
,
Stress
,
Tension
An In Vivo Method for Measuring Turbulence in Mechanical Prosthesis Leakage Jets
Brandon R. Travis, Ph.D., Thomas D. Christensen, M.D., Morten Smerup, M.D., Morten S. Olsen, M.S., J. Michael Hasenkam, M.D., D.M.Sc., Hans Nygaard, M.S., D.M.Sc.
J Biomech Eng. February 2004, 126(1): 26–35.
doi: https://doi.org/10.1115/1.1644563
Topics:
Jets
,
Leakage
,
Stress
,
Turbulence
,
Velocity measurement
,
Valves
,
Shear stress
,
Errors
Intra-Aneurysmal Flow With Helix and Mesh Stent Placement Across Side-Wall Aneurysm Pore of a Straight Parent Vessel
J Biomech Eng. February 2004, 126(1): 36–43.
doi: https://doi.org/10.1115/1.1644566
Topics:
Aneurysms
,
Flow (Dynamics)
,
Stents
,
Vessels
,
Shear stress
3-D Anatomically Based Dynamic Modeling of the Human Knee to Include Tibio-Femoral and Patello-Femoral Joints
J Biomech Eng. February 2004, 126(1): 44–53.
doi: https://doi.org/10.1115/1.1644565
Topics:
Knee
,
Tendons
,
Stress
,
Kinematics
,
Dynamic response
A Novel Robotic System for Joint Biomechanical Tests: Application to the Human Knee Joint
J Biomech Eng. February 2004, 126(1): 54–61.
doi: https://doi.org/10.1115/1.1644567
Topics:
Biomechanics
,
Displacement
,
Errors
,
Knee
,
Manipulators
,
Robotics
,
Stress
How Cyclic Loading Affects the Migration of Radio-Opaque Markers Attached to Tendon Grafts Using a New Method: A Study Using Roentgen Stereophotogrammetric Analysis (RSA)
J Biomech Eng. February 2004, 126(1): 62–69.
doi: https://doi.org/10.1115/1.1644568
Topics:
Anterior cruciate ligament
,
Errors
,
Tantalum
,
Tendons
,
Tunnels
,
Cycles
,
Soft tissues
,
Stainless steel
Effects of Ischemia on Epicardial Deformation in the Passive Rabbit Heart
Glenn R. Gaudette, Ph.D., Irvin B. Krukenkamp, M.D., Evren U. Azeloglu, Adam E. Saltman, J.D., Ph.D., Miriam Lense, Joseph Todaro, M.S.M.E., Fu-Pen Chiang, Ph.D.
J Biomech Eng. February 2004, 126(1): 70–75.
doi: https://doi.org/10.1115/1.1645524
Topics:
Deformation
,
Pressure
,
Resolution (Optics)
,
Displacement
,
Myocardium
,
Stress
,
Tensors
,
Biological tissues
,
Particulate matter
,
Surgery
Mechanical Properties of Rat Middle Cerebral Arteries With and Without Myogenic Tone
J Biomech Eng. February 2004, 126(1): 76–81.
doi: https://doi.org/10.1115/1.1645525
Topics:
Cerebral arteries
,
Pressure
,
Surface mount components
,
Vessels
,
Mechanical properties
,
Muscle
,
Stiffness
An Integrated Finite-Element Approach to Mechanics, Transport and Biosynthesis in Tissue Engineering
J Biomech Eng. February 2004, 126(1): 82–91.
doi: https://doi.org/10.1115/1.1645526
Topics:
Biological tissues
,
Compression
,
Diffusion (Physics)
,
Finite element analysis
,
Fluids
,
Macromolecules
,
Tissue engineering
,
Cartilage
,
Deformation
,
Pressure
An Improved Method to Analyze the Stress Relaxation of Ligaments Following a Finite Ramp Time Based on the Quasi-Linear Viscoelastic Theory
J Biomech Eng. February 2004, 126(1): 92–97.
doi: https://doi.org/10.1115/1.1645528
Topics:
Relaxation (Physics)
,
Stress
,
Biological tissues
,
Errors
Determinants of Left Ventricular Shape Change During Filling
J Biomech Eng. February 2004, 126(1): 98–103.
doi: https://doi.org/10.1115/1.1645527
Mechanical Properties of a Reversible, DNA-Crosslinked Polyacrylamide Hydrogel
J Biomech Eng. February 2004, 126(1): 104–110.
doi: https://doi.org/10.1115/1.1645529
Topics:
DNA
,
Hydrogels
,
Viscosity
,
Density
,
Elastic moduli
,
Mechanical properties
Experimental and Numerical Modeling of Variable Friction Between Nanoregions in Conventional and Crosslinked UHMWPE
J Biomech Eng. February 2004, 126(1): 111–119.
doi: https://doi.org/10.1115/1.1645530
Topics:
Friction
,
Stress
,
Deformation
,
Atomic force microscopy
,
Wear
,
Nanoscale phenomena
Technical Briefs
Mechanical Properties of Shock-Absorbing Pylons Used in Transtibial Prostheses
J Biomech Eng. February 2004, 126(1): 120–122.
doi: https://doi.org/10.1115/1.1645865
Topics:
Artificial limbs
,
Damping
,
Displacement
,
Elastic constants
,
Mechanical properties
,
Prostheses
,
Shock (Mechanics)
,
Testing
,
Springs
,
Transients (Dynamics)
Preparation of On-Axis Cylindrical Trabecular Bone Specimens Using Micro-CT Imaging
J Biomech Eng. February 2004, 126(1): 122–125.
doi: https://doi.org/10.1115/1.1645866
Topics:
Bone
,
Mechanical testing
,
Imaging
,
Resolution (Optics)
,
Textiles
Email alerts
RSS Feeds
Improvement in Active Cell Proliferation Area at Higher Permeability With Novel TPMS Lattice Structure
J Biomech Eng (November 2024)
A Numerical Study of Crack Penetration and Deflection at the Interface Between Peritubular and Intertubular Dentin
J Biomech Eng (December 2024)