Abstract

Plate fractures after fixation of a Vancouver Type B1 periprosthetic femoral fracture (PFF) are difficult to treat and could lead to severe disability. However, due to the lack of direct measurement of in vivo performance of the PFF fixation construct, it is unknown whether current standard mechanical tests or previous experimental and computational studies have appropriately reproduced the in vivo mechanics of the plate. To provide a basis for the evaluation and development of appropriate mechanical tests for assessment of plate fracture risk, this study applied loads of common activities of daily living (ADLs) to implanted femur finite element (FE) models with PFF fixation constructs with an existing or a healed PFF. Based on FE simulated plate mechanics, the standard four-point-bend test adequately matched the stress state and the resultant bending moment in the plate as compared with femur models with an existing PFF. In addition, the newly developed constrained three-point-bend tests were able to reproduce plate stresses in models with a healed PFF. Furthermore, a combined bending and compression cadaveric test was appropriate for risk assessment including both plate fracture and screw loosening after the complete healing of PFF. The result of this study provides the means for combined experimental and computational preclinical evaluation of PFF fixation constructs.

References

1.
Marsland
,
D.
, and
Mears
,
S. C.
,
2012
, “
A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty
,”
Geriatr. Orthop. Surg. Rehabil.
,
3
(
3
), pp.
107
120
.10.1177/2151458512462870
2.
Lindahl
,
H.
,
Malchau
,
H.
,
Odén
,
A.
, and
Garellick
,
G.
,
2006
, “
Risk Factors for Failure After Treatment of a Periprosthetic Fracture of the Femur
,”
J. Bone Jt. Surg. - Ser. B
,
88-B
(
1
), pp.
26
30
.10.1302/0301-620X.88B1.17029
3.
Corten
,
K.
,
Vanrykel
,
F.
,
Bellemans
,
J.
,
Reynders Frederix
,
P.
,
Simon
,
J. P.
, and
Broos
,
P. L. O.
,
2009
, “
An Algorithm for the Surgical Treatment of Periprosthetic Fractures of the Femur Around a Well-Fixed Femoral Component
,”
J. Bone Jt. Surg. Ser. B
,
91-B
(
11
), pp.
1424
1430
.10.1302/0301-620X.91B11.22292
4.
Lindahl
,
H.
,
Oden
,
A.
,
Garellick
,
G.
, and
Malchau
,
H.
,
2007
, “
The Excess Mortality Due to Periprosthetic Femur Fracture. A Study From the Swedish National Hip Arthroplasty Register
,”
Bone
,
40
(
5
), pp.
1294
1298
.10.1016/j.bone.2007.01.003
5.
Lever
,
J. P.
,
Zdero
,
R.
,
Nousiainen
,
M. T.
,
Waddell
,
J. P.
, and
Schemitsch
,
E. H.
,
2010
, “
The Biomechanical Analysis of Three Plating Fixation Systems for Periprosthetic Femoral Fracture Near the Tip of a Total Hip Arthroplasty
,”
J. Orthop. Surg. Res.
,
5
(
1
), pp.
1
8
.10.1186/1749-799X-5-45
6.
Duncan
,
C. P.
, and
Haddad
,
F. S.
,
2014
, “
The Unified Classification System (UCS): Improving Our Understanding of Periprosthetic Fractures
,”
Bone Jt. J.
,
96-B
(
6
), pp.
713
716
.10.1302/0301-620X.96B6.34040
7.
Boesmueller
,
S.
,
Baumbach
,
S. F.
,
Hofbauer
,
M.
, and
Wozasek
,
G. E.
,
2015
, “
Plate Failure Following Plate Osteosynthesis in Periprosthetic Femoral Fractures
,”
Wien. Klin. Wochenschr.
,
127
(
19–20
), pp.
770
778
.10.1007/s00508-015-0818-3
8.
Giovanni
,
V.
,
Davide
,
B.
,
Giuseppe
,
S.
,
Massimiliano
,
C.
,
Alberto
,
B.
,
Antonio
,
D. A.
,
Oronzo
,
D. C.
, and
Biagio
,
M.
,
2020
, “
Periprosthetic Femoral Re-Fractures Pathogenesis, Classification, and Surgical Implications
,”
Injury
, epub.10.1016/j.injury.2020.11.030
9.
Randelli
,
F.
,
Pace
,
F.
,
Priano
,
D.
,
Giai Via
,
A.
, and
Randelli
,
P.
,
2018
, “
Re-Fractures After Periprosthetic Femoral Fracture: A Difficult to Treat Growing Evidence
,”
Injury
,
49
, pp.
S43
S47
.10.1016/j.injury.2018.09.045
10.
Min
,
B.-W.
,
Lee
,
K.-J.
,
Cho
,
C.-H.
,
Lee
,
I.-G.
, and
Kim
,
B.-S.
,
2020
, “
High Failure Rates of Locking Compression Plate Osteosynthesis With Transverse Fracture Around a Well-Fixed Stem Tip for Periprosthetic Femoral Fracture
,”
J. Clin. Med.
,
9
(
11
), p.
3758
.10.3390/jcm9113758
11.
Lenz
,
M.
,
Stoffel
,
K.
,
Kielstein
,
H.
,
Mayo
,
K.
,
Hofmann
,
G. O.
, and
Gueorguiev
,
B.
,
2016
, “
Plate Fixation in Periprosthetic Femur Fractures Vancouver Type B1—Trochanteric Hook Plate or Subtrochanterical Bicortical Locking?
,”
Injury
,
47
(
12
), pp.
2800
2804
.10.1016/j.injury.2016.09.037
12.
Lenz
,
M.
,
Stoffel
,
K.
,
Gueorguiev
,
B.
,
Klos
,
K.
,
Kielstein
,
H.
, and
Hofmann
,
G. O.
,
2016
, “
Enhancing Fixation Strength in Periprosthetic Femur Fractures by Orthogonal Plating - A Biomechanical Study
,”
J. Orthop. Res.
,
34
(
4
), pp.
591
596
.10.1002/jor.23065
13.
ASTM International
,
2008
, “
Standard Specification and Test Method for Metallic Bone Plates
,” Report No. F382-99, pp.
1
12
.
14.
Moazen
,
M.
,
Mak
,
J. H.
,
Etchels
,
L. W.
,
Jin
,
Z.
,
Wilcox
,
R. K.
,
Jones
,
A. C.
, and
Tsiridis
,
E.
,
2013
, “
The Effect of Fracture Stability on the Performance of Locking Plate Fixation in Periprosthetic Femoral Fractures
,”
J. Arthroplasty
,
28
(
9
), pp.
1589
1595
.10.1016/j.arth.2013.03.022
15.
Moazen
,
M.
,
Mak
,
J. H.
,
Etchels
,
L. W.
,
Jin
,
Z.
,
Wilcox
,
R. K.
,
Jones
,
A. C.
, and
Tsiridis
,
E.
,
2014
, “
Periprosthetic Femoral Fracture - A Biomechanical Comparison Between Vancouver Type B1 and B2 Fixation Methods
,”
J. Arthroplasty
,
29
(
3
), pp.
495
500
.10.1016/j.arth.2013.08.010
16.
Choi
,
J. K.
,
Gardner
,
T. R.
,
Yoon
,
E.
,
Morrison
,
T. A.
,
Macaulay
,
W. B.
, and
Geller
,
J. A.
,
2010
, “
The Effect of Fixation Technique on the Stiffness of Comminuted Vancouver B1 Periprosthetic Femur Fractures
,”
J. Arthroplasty
,
25
(
Suppl. 6
), pp.
124
128
.10.1016/j.arth.2010.04.009
17.
Wang
,
K.
,
Kenanidis
,
E.
,
Miodownik
,
M.
,
Tsiridis
,
E.
, and
Moazen
,
M.
,
2019
, “
Periprosthetic Fracture Fixation of the Femur Following Total Hip Arthroplasty: A Review of Biomechanical Testing – Part II
,”
Clin. Biomech.
,
61
(
December 2018
), pp.
144
162
.10.1016/j.clinbiomech.2018.12.001
18.
Moazen
,
M.
,
Jones
,
A. C.
,
Jin
,
Z.
,
Wilcox
,
R. K.
, and
Tsiridis
,
E.
,
2011
, “
Periprosthetic Fracture Fixation of the Femur Following Total Hip Arthroplasty: A Review of Biomechanical Testing
,”
Clin. Biomech.
,
26
(
1
), pp.
13
22
.10.1016/j.clinbiomech.2010.09.002
19.
Dhason
,
R.
,
Roy
,
S.
, and
Datta
,
S.
,
2020
, “
A Biomechanical Study on the Laminate Stacking Sequence in Composite Bone Plates for Vancouver Femur B1 Fracture Fixation
,”
Comput. Methods Programs Biomed.
,
196
, p.
105680
.10.1016/j.cmpb.2020.105680
20.
Chen
,
X.
,
Myers
,
C. A.
,
Clary
,
C. W.
,
DeWall
,
R. J.
,
Fritz
,
B.
,
Blauth
,
M.
, and
Rullkoetter
,
P. J.
,
2021
, “
Development of Axial Compression and Combined Axial Compression and Torque Loading Configurations to Reproduce Strain in the Implanted Femur During Activities of Daily Living
,”
J. Biomech.
,
120
, p.
110363
.10.1016/j.jbiomech.2021.110363
21.
Duda
,
G. N.
,
Heller
,
M.
,
Albinger
,
J.
,
Schulz
,
O.
,
Schneider
,
E.
, and
Claes
,
L.
,
1998
, “
Influence of Muscle Forces on Femoral Strain Distribution
,”
J. Biomech.
,
31
(
9
), pp.
841
846
.10.1016/S0021-9290(98)00080-3
22.
Speirs
,
A. D.
,
Heller
,
M. O.
,
Duda
,
G. N.
, and
Taylor
,
W. R.
,
2007
, “
Physiologically Based Boundary Conditions in Finite Element Modelling
,”
J. Biomech.
,
40
(
10
), pp.
2318
2323
.10.1016/j.jbiomech.2006.10.038
23.
Taylor
,
M. E.
,
Tanner
,
K. E.
,
Freeman
,
M. A. R.
, and
Yettram
,
A. L.
,
1996
, “
Elsevicr Science Lrd for IPEMB Stress and Strain Distribution Within the Intact Femur: Compression or Bending?
,”
Med. Eng. Hys.
,
18
(
2
), pp.
122
131
.10.1016/1350-4533(95)00031-3
24.
Chantarapanich
,
N.
,
Sitthiseripratip
,
K.
,
Mahaisavariya
,
B.
, and
Siribodhi
,
P.
,
2016
, “
Biomechanical Performance of Retrograde Nail for Supracondylar Fractures Stabilization
,”
Med. Biol. Eng. Comput.
,
54
(
6
), pp.
939
952
.10.1007/s11517-016-1466-0
25.
Jitprapaikulsarn
,
S.
,
Chantarapanich
,
N.
,
Gromprasit
,
A.
,
Mahaisavariya
,
C.
, and
Patamamongkonchai
,
C.
,
2021
, “
Single Lag Screw and Reverse Distal Femur Locking Compression Plate for Concurrent Cervicotrochanteric and Shaft Fractures of the Femur: Biomechanical Study Validated With a Clinical Series
,” Eur.
J. Orthop. Surg. Traumatol.
,
31
(
6
), pp.
1179
1192
.10.1007/s00590-020-02868-z
26.
Schileo
,
E.
,
Dall'Ara
,
E.
,
Taddei
,
F.
,
Malandrino
,
A.
,
Schotkamp
,
T.
,
Baleani
,
M.
, and
Viceconti
,
M.
,
2008
, “
An Accurate Estimation of Bone Density Improves the Accuracy of Subject-Specific Finite Element Models
,”
J. Biomech.
,
41
(
11
), pp.
2483
2491
.10.1016/j.jbiomech.2008.05.017
27.
Morgan
,
E. F.
,
Bayraktar
,
H. H.
, and
Keaveny
,
T. M.
,
2003
, “
Trabecular Bone Modulus-Density Relationships Depend on Anatomic Site
,”
J. Biomech.
,
36
(
7
), pp.
897
904
.10.1016/S0021-9290(03)00071-X
28.
Taddei
,
F.
,
Schileo
,
E.
,
Helgason
,
B.
,
Cristofolini
,
L.
, and
Viceconti
,
M.
,
2007
, “
The Material Mapping Strategy Influences the Accuracy of CT-Based Finite Element Models of Bones: An Evaluation Against Experimental Measurements
,”
Med. Eng. Phys.
,
29
(
9
), pp.
973
979
.10.1016/j.medengphy.2006.10.014
29.
2013
,
ASTM F138-13a
, “
Standard Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for Surgical Implants (UNS S31673)
,” Report No. F138-19, pp.
1
6
.
30.
Avval
,
P. T.
,
Samiezadeh
,
S.
, and
Bougherara
,
H.
,
2016
, “
Long-Term Response of Femoral Density to Hip Implant and Bone Fracture Plate: Computational Study Using a Mechano-Biochemical Model
,”
Med. Eng. Phys.
,
38
(
2
), pp.
171
180
.10.1016/j.medengphy.2015.11.013
31.
Ebrahimi
,
H.
,
Rabinovich
,
M.
,
Vuleta
,
V.
,
Zalcman
,
D.
,
Shah
,
S.
,
Dubov
,
A.
,
Roy
,
K.
,
Siddiqui
,
F. S.
,
Schemitsch
,
E. H.
,
Bougherara
,
H.
, and
Zdero
,
R.
,
2012
, “
Biomechanical Properties of an Intact, Injured, Repaired, and Healed Femur: An Experimental and Computational Study
,”
J. Mech. Behav. Biomed. Mater.
,
16
(
1
), pp.
121
135
.10.1016/j.jmbbm.2012.09.005
32.
Myers
,
C. A.
,
Laz
,
P. J.
,
Shelburne
,
K. B.
,
Judd
,
D. L.
,
Huff
,
D. N.
,
Winters
,
J. D.
,
Stevens-Lapsley
,
J. E.
, and
Rullkoetter
,
P. J.
,
2018
, “
The Impact of Hip Implant Alignment on Muscle and Joint Loading During Dynamic Activities
,”
Clin. Biomech.
,
53
(
February
), pp.
93
100
.10.1016/j.clinbiomech.2018.02.010
33.
Leonidou
,
A.
,
Moazen
,
M.
,
Lepetsos
,
P.
,
Graham
,
S. M.
,
Macheras
,
G. A.
, and
Tsiridis
,
E.
,
2015
, “
The Biomechanical Effect of Bone Quality and Fracture Topography on Locking Plate Fixation in Periprosthetic Femoral Fractures
,”
Injury
,
46
(
2
), pp.
213
217
.10.1016/j.injury.2014.10.060
34.
Takahashi
,
D.
,
Noyama
,
Y.
,
Asano
,
T.
,
Shimizu
,
T.
,
Irie
,
T.
,
Terkawi
,
M. A.
, and
Iwasaki
,
N.
,
2021
, “
Finite Element Analysis of Double‐Plate Fixation Using Reversed Locking Compression‐Distal Femoral Plates for Vancouver B1 Periprosthetic Femoral Fractures
,”
BMC Musculoskelet. Disord.
,
22
(
1
), pp.
1
8
.10.1186/s12891-021-04152-5
35.
Moazen
,
M.
,
Leonidou
,
A.
,
Pagkalos
,
J.
,
Marghoub
,
A.
,
Fagan
,
M. J.
, and
Tsiridis
,
E.
,
2016
, “
Application of Far Cortical Locking Technology in Periprosthetic Femoral Fracture Fixation: A Biomechanical Study
,”
J. Arthroplasty
,
31
(
8
), pp.
1849
1856
.10.1016/j.arth.2016.02.013
36.
Ottesen
,
T. D.
,
McLynn
,
R. P.
,
Galivanche
,
A. R.
,
Bagi
,
P. S.
,
Zogg
,
C. K.
,
Rubin
,
L. E.
, and
Grauer
,
J. N.
,
2018
, “
Increased Complications in Geriatric Patients With a Fracture of the Hip Whose Postoperative Weight-Bearing is Restricted: An Analysis of 4918 Patients
,”
Bone Jt. J.
,
100-B
(
10
), pp.
1377
1384
.10.1302/0301-620X.100B10.BJJ-2018-0489.R1
37.
Warren
,
J.
,
Sundaram
,
K.
,
Anis
,
H.
,
McLaughlin
,
J.
,
Patterson
,
B.
,
Higuera
,
C. A.
, and
Piuzzi
,
N. S.
,
2019
, “
The Association Between Weight-Bearing Status and Early Complications in Hip Fractures
,”
Eur. J. Orthop. Surg. Traumatol.
,
29
(
7
), pp.
1419
1427
.10.1007/s00590-019-02453-z
38.
Pletka
,
J. D.
,
Marsland
,
D.
,
Belkoff
,
S. M.
,
Mears
,
S. C.
, and
Kates
,
S. L.
,
2011
, “
Biomechanical Comparison of 2 Different Locking Plate Fixation Methods in Vancouver B1 Periprosthetic Femur Fractures
,”
Geriatr. Orthop. Surg. Rehabil.
,
2
(
2
), pp.
51
55
.10.1177/2151458510397609
You do not currently have access to this content.