Located on the right side of the heart, the tricuspid valve (TV) prevents blood backflow from the right ventricle to the right atrium. Similar to other cardiac valves, quantification of TV biaxial mechanical properties is essential in developing accurate computational models. In the current study, for the first time, the biaxial stress–strain behavior of porcine TV was measured ex vivo under different loading protocols using biaxial tensile testing equipment. The results showed a highly nonlinear response including a compliant region followed by a rapid transition to a stiff region for all of the TV leaflets both in the circumferential and in the radial directions. Based on the data analysis, all three leaflets were found to be anisotropic, and they were stiffer in the circumferential direction in comparison to the radial direction. It was also concluded that the posterior leaflet was the most anisotropic leaflet.
Skip Nav Destination
Article navigation
October 2016
Technical Briefs
On the Biaxial Mechanical Response of Porcine Tricuspid Valve Leaflets
Keyvan Amini Khoiy,
Keyvan Amini Khoiy
Department of Biomedical Engineering,
The University of Akron,
Olson Research Center, Room 322/3,
260 South Forge Street,
Akron, OH 44325
e-mail: ka67@zips.uakron.edu
The University of Akron,
Olson Research Center, Room 322/3,
260 South Forge Street,
Akron, OH 44325
e-mail: ka67@zips.uakron.edu
Search for other works by this author on:
Rouzbeh Amini
Rouzbeh Amini
Mem. ASME
Department of Biomedical Engineering,
The University of Akron,
Olson Research Center, Room 301F,
260 South Forge Street,
Akron, OH 44325
e-mail: ramini@uakron.edu
Department of Biomedical Engineering,
The University of Akron,
Olson Research Center, Room 301F,
260 South Forge Street,
Akron, OH 44325
e-mail: ramini@uakron.edu
Search for other works by this author on:
Keyvan Amini Khoiy
Department of Biomedical Engineering,
The University of Akron,
Olson Research Center, Room 322/3,
260 South Forge Street,
Akron, OH 44325
e-mail: ka67@zips.uakron.edu
The University of Akron,
Olson Research Center, Room 322/3,
260 South Forge Street,
Akron, OH 44325
e-mail: ka67@zips.uakron.edu
Rouzbeh Amini
Mem. ASME
Department of Biomedical Engineering,
The University of Akron,
Olson Research Center, Room 301F,
260 South Forge Street,
Akron, OH 44325
e-mail: ramini@uakron.edu
Department of Biomedical Engineering,
The University of Akron,
Olson Research Center, Room 301F,
260 South Forge Street,
Akron, OH 44325
e-mail: ramini@uakron.edu
1Corresponding author.
Manuscript received December 4, 2015; final manuscript received August 1, 2016; published online August 24, 2016. Assoc. Editor: Jonathan Vande Geest.
J Biomech Eng. Oct 2016, 138(10): 104504 (6 pages)
Published Online: August 24, 2016
Article history
Received:
December 4, 2015
Revised:
August 1, 2016
Citation
Amini Khoiy, K., and Amini, R. (August 24, 2016). "On the Biaxial Mechanical Response of Porcine Tricuspid Valve Leaflets." ASME. J Biomech Eng. October 2016; 138(10): 104504. https://doi.org/10.1115/1.4034426
Download citation file:
Get Email Alerts
Related Articles
Biaxial Mechanical Properties of the Natural and Glutaraldehyde Treated Aortic Valve Cusp—Part I: Experimental Results
J Biomech Eng (February,2000)
Mechanical Characterization of Anisotropic Planar Biological Soft
Tissues Using Large Indentation: A Computational Feasibility
Study
J Biomech Eng (June,2006)
Direct Measurement of Nonuniform Large Deformations in Soft Tissues During Uniaxial Extension
J Biomech Eng (June,2009)
Simulated Bioprosthetic Heart Valve Deformation under Quasi-Static Loading
J Biomech Eng (November,2005)
Related Proceedings Papers
Related Chapters
Tissue and blood-material interactions
Biocompatible Nanomaterials for Targeted and Controlled Delivery of Biomacromolecules
Hemolysis
Mechanical Blood Trauma in Circulatory-Assist Devices
Basic Concepts
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range