Since the direction of the quadriceps force and location of the patellofemoral contact point likely differ between axial and multiplane loadings, the force and moment balance solutions for a multiplane loading condition may not yield the same patella ligament force/quadriceps force ratio ( ratio) when compared with an axial loading condition. The purpose of this study was to compare the effects of an axial loading condition and an anatomical, multiplane loading condition on the ratio at various knee flexion angles. Ten cadaver knees were used in this investigation. Each was mounted on a custom jig that was fixed to an Instron frame. Quadriceps muscle loads were applied with same resultant force magnitudes under two force directions, as follows: (1) axial loading (central quadriceps tendon loading parallel to the femoral axis), and (2) an anatomically based, multiplane loading condition (individual vasti loaded, taking into consideration physiologic muscle fiber orientation). Patellar ligament tension was measured using a buckle transducer. The patellar ligament force/quadriceps force ratio ( ratio) was calculated for both loading conditions at 0 deg, 20 deg, 40 deg, and 60 deg of knee flexion. Across the range of knee motion evaluated, the ratio for the axial loading condition was significantly greater than the ratio for the multiplane loading condition. Our results suggest that loading orientation affects the transfer of forces from the quadriceps tendon to the patellar ligament.
Skip Nav Destination
e-mail: powers@usc.edu
Article navigation
February 2010
Technical Briefs
Multiplane Loading of the Extensor Mechanism Alters the Patellar Ligament Force/Quadriceps Force Ratio
Christopher M. Powers,
Christopher M. Powers
P.T.
Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology and Physical Therapy,
e-mail: powers@usc.edu
University of Southern California
, Los Angeles, CA 90036
Search for other works by this author on:
Yu-Jen Chen,
Yu-Jen Chen
P.T.
Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology and Physical Therapy,
University of Southern California
, Los Angeles, CA 90036
Search for other works by this author on:
Irving S. Scher,
Irving S. Scher
P.E.
Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology and Physical Therapy,
University of Southern California
, Los Angeles, CA 90036
Search for other works by this author on:
Thay Q. Lee
Thay Q. Lee
Orthopaedic Biomechanics Laboratory VA Long Beach Healthcare System, Long Beach, CA Departments of Orthopaedic Surgery,
University of California
, Irvine, CA 92697
Search for other works by this author on:
Christopher M. Powers
P.T.
Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology and Physical Therapy,
University of Southern California
, Los Angeles, CA 90036e-mail: powers@usc.edu
Yu-Jen Chen
P.T.
Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology and Physical Therapy,
University of Southern California
, Los Angeles, CA 90036
Irving S. Scher
P.E.
Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology and Physical Therapy,
University of Southern California
, Los Angeles, CA 90036
Thay Q. Lee
Orthopaedic Biomechanics Laboratory VA Long Beach Healthcare System, Long Beach, CA Departments of Orthopaedic Surgery,
University of California
, Irvine, CA 92697J Biomech Eng. Feb 2010, 132(2): 024503 (5 pages)
Published Online: January 29, 2010
Article history
Received:
March 25, 2008
Revised:
October 2, 2009
Posted:
December 17, 2009
Published:
January 29, 2010
Online:
January 29, 2010
Citation
Powers, C. M., Chen, Y., Scher, I. S., and Lee, T. Q. (January 29, 2010). "Multiplane Loading of the Extensor Mechanism Alters the Patellar Ligament Force/Quadriceps Force Ratio." ASME. J Biomech Eng. February 2010; 132(2): 024503. https://doi.org/10.1115/1.4000852
Download citation file:
Get Email Alerts
A Numerical Study of Crack Penetration and Deflection at the Interface Between Peritubular and Intertubular Dentin
J Biomech Eng (December 2024)
Related Articles
Design and Validation of a General Purpose Robotic Testing System for Musculoskeletal Applications
J Biomech Eng (February,2010)
A Biomechanical Model of the Foot: The Role of Muscles, Tendons, and Ligaments
J Biomech Eng (June,2002)
Determination of Passive Moment-Angle Relationships at the Trapeziometacarpal Joint
J Biomech Eng (July,2010)
Related Chapters
A New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee Joint
Skiing Trauma and Safety: Tenth Volume
Oscillation of Airway Smooth Muscle as a Potential Non-Medicinal Treatment for Asthma
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Health and Safety and Emergency Response
Pipeline Transportation of Carbon Dioxide Containing Impurities