0
Research Papers

Mechanical Properties of Viscoelastic Media by Local Frequency Estimation of Divergence-Free Wave Fields

[+] Author and Article Information
Erik H. Clayton

e-mail: clayton@wustl.edu

Ruth J. Okamoto

Department of Mechanical Engineering and Materials Science,
Washington University in St. Louis,
One Brookings Drive,
Campus Box 1185,
Saint Louis, MO 63130

Philip V. Bayly

Department of Mechanical Engineering and Materials Science,
Washington University in St. Louis,
One Brookings Drive,
Campus Box 1185,
Saint Louis, MO 63130;
Department of Biomedical Engineering,
Washington University in St. Louis,
One Brookings Drive,
Campus Box 1185,
Saint Louis, MO 63130

1Corresponding author.

Contributed by the Bioengineering Division of ASME for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received October 1, 2012; final manuscript received January 14, 2013; accepted manuscript posted January 18, 2013; published online February 7, 2013. Editor: Victor H. Barocas.

J Biomech Eng 135(2), 021025 (Feb 07, 2013) (6 pages) Paper No: BIO-12-1447; doi: 10.1115/1.4023433 History: Received October 01, 2012; Revised January 14, 2013; Accepted January 18, 2013

Magnetic resonance elastography (MRE) is an imaging modality with which mechanical properties can be noninvasively measured in living tissue. Magnetic resonance elastography relies on the fact that the elastic shear modulus determines the phase velocity and, hence the wavelength, of shear waves which are visualized by motion-sensitive MR imaging. Local frequency estimation (LFE) has been used to extract the local wavenumber from displacement wave fields recorded by MRE. LFE -based inversion is attractive because it allows material parameters to be estimated without explicitly invoking the equations governing wave propagation, thus obviating the need to numerically compute the Laplacian. Nevertheless, studies using LFE have not explicitly addressed three important issues: (1) tissue viscoelasticity; (2) the effects of longitudinal waves and rigid body motion on estimates of shear modulus; and (3) mechanical anisotropy. In the current study we extend the LFE technique to (1) estimate the (complex) viscoelastic shear modulus in lossy media; (2) eliminate the effects of longitudinal waves and rigid body motion; and (3) determine two distinct shear moduli in anisotropic media. The extended LFE approach is demonstrated by analyzing experimental data from a previously-characterized, isotropic, viscoelastic, gelatin phantom and simulated data from a computer model of anisotropic (transversely isotropic) soft material.

FIGURES IN THIS ARTICLE
<>
Copyright © 2013 by ASME
Your Session has timed out. Please sign back in to continue.

References

Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., and Ehman, R. L., 1995, “Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves,” Science, 269(5232), pp. 1854–1857. [CrossRef] [PubMed]
Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., 2000, “Tissue Characterization Using Magnetic Resonance Elastography: Preliminary Results,” Phys. Med. Biol., 45(6), pp.1579–1590. [CrossRef] [PubMed]
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., and Holtz, D., 2000, “High-Resolution Tensor MR Elastography for Breast Tumour Detection,” Phys. Med. Biol., 45(6), pp. 1649–1664. [CrossRef] [PubMed]
Braun, J., Buntkowsky, G., Bernarding, J., Tolxdorff, T., and Sack, I., 2011, “Simulation and Analysis of Magnetic Resonance Elastography Wave Images Using Coupled Harmonic Oscillators and Gaussian Local Frequency Estimation,” Magn. Reson. Imaging, 19(5), pp. 703–713. [CrossRef]
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., Ehman, R. L., 2001, “Magnetic Resonance Elastography: Non-Invasive Mapping of Tissue Elasticity,” Med. Image Anal., 5(4), pp. 237–254. [CrossRef] [PubMed]
Van Houten, E. E., Paulsen, K. D., Miga, M. I., Kennedy, F. E., and Weaver, J. B., 1999, “An Overlapping Subzone Technique for MR-Based Elastic Property Reconstruction,” Magn. Reson. Med., 42(4), pp. 779–786. [CrossRef] [PubMed]
Sinkus, R., Tanter, M., Xydeas, T., Catheline, S., Bercoff, J., and Fink, M., 2005, “Viscoelastic Shear Properties of In Vivo Breast Lesions Measured by MR Elastography,” J. Magn. Reson. Imaging, 23(2), pp. 159–165. [CrossRef]
Klatt, D., Hamhaber, U., Asbach, P., Braun, J., and Sack, I.,2007, “Noninvasive Assessment of the Rheological Behavior of Human Organs Using Multifrequency MR Elastography: A Study of Brain and Liver Viscoelasticity,” Phys. Med. Biol., 52(24), pp. 7281–7294. [CrossRef] [PubMed]
Green, M. A., Bilston, L. E., and Sinkus, R., 2008, “In Vivo Brain Viscoelastic Properties Measured by Magnetic Resonance Elastography,” NMR Biomed., 21(7), pp. 755–764. [CrossRef] [PubMed]
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., and Braun, J., 2008, “Non–invasive Measurement of Brain Viscoelasticity Using Magnetic Resonance Elastography,” NMR Biomed., 21, pp. 265–271. [CrossRef] [PubMed]
Sack, I., Rump, J., Elgeti, T., Samani, A., and Braun, J., 2009, “MR Elastography of the Human Heart: Noninvasive Assessment of Myocardial Elasticity Changes By Shear Wave Amplitude Variations,” Magn. Reson. Med., 61(3), pp. 668–677. [CrossRef] [PubMed]
Klatt, D., Papazoglou, S., Braun, J., and Sack, I., 2010, “Viscoelasticity-Based MR Elastography of Skeletal Muscle,” Phys. Med. Biol., 55, pp. 6445–6459. [CrossRef] [PubMed]
Streitberger, K. J., Wiener, E., Hoffmann, J., Freimann, F. B., Klatt, D., Braun, J., Lin, K., McLaughlin, J., Sprung, C., Klingebiel, R., Sack, I., 2010, “In Vivo Viscoelastic Properties of the Brain in Normal Pressure Hydrocephalus,” NMR Biomed., 24(7), pp. 385–392. [PubMed]
Wuerfel, J., Paul, F., Beierbach, B., Hamhaber, U., Klatt, D., Papazoglou, S., Zipp, F., Martus, P., Braun, J., Sack, I., 2010, “MR-Elastography Reveals Degradation of Tissue Integrity in Multiple Sclerosis,” Neuroimage, 49(3), pp. 2520–2525. [CrossRef] [PubMed]
Clayton, E. H., Garbow, J. R., and Bayly, P. V., 2011, “Frequency-Dependent Viscoelastic Parameters of Mouse Brain Tissue Estimated by MR Elastography,” Phys. Med. Biol., 56(8), pp. 2391–2406. [CrossRef] [PubMed]
Riek, K., Klatt, D., Nuzha, H., Mueller, S., Neumann, U., Sack, I., Braun, J., 2011, “Wide-Range Dynamic Magnetic Resonance Elastography,” J. Biomech., 44(7), pp. 1380–1386. [CrossRef] [PubMed]
Clayton, E. H., Genin, G. M., and Bayly, P. V., 2012, “Transmission, Attenuation and Reflection of Shear Waves in the Human Brain,” J. R. Soc., Interface, 76, pp. 2899–2910. [CrossRef]
Chatelin, S., Constantinesco, A., and Willinger, R., 2010, “Fifty Years of Brain Tissue Mechanical Testing: From In Vitro to In Vivo Investigations,” Biorheology, 47(5-6), pp. 255–276. [PubMed]
Whitham, G. B., 1974, Linear and Nonlinear Waves, Wiley, New York.
Okamoto, R. J., Clayton, E. H., and Bayly, P. V., 2011, “Viscoelastic Properties of Soft Gels: Comparison of Magnetic Resonance Elastography and Dynamic Shear Testing in the Shear Wave Regime,” Phys. Med. Biol., 56(19), pp. 6379–6400. [CrossRef] [PubMed]
Knutsson, H., Westin, C. F., and Granlund, G. H., 1994, “Local Multiscale Frequency and Bandwidth Estimation,” Proceedings of the IEEE International Conference on Image Processing, pp. 36–40.
Grimm, R. C., Lake, D. S., Manduca, A., Ehman, R. L., 2006, MRE/Wave version: 1 July 2006, Mayo Clinic, http://mayoresearch.mayo.edu/mayo/research/ehman lab/mrw-wave.cfm
Kolsky, H., 1963, Stress Waves in Solids, Dover, New York.
Auld, B. A., 1990, Acoustic Fields and Waves in Solids, R.E. Krieger, Malabar, FL.
Christensen, R. M., 2005, Mechanics of Composite Materials, Dover, New York.
Clayton, E. H., 2012, “Magnetic Resonance Elastography of the Brain: From Phantom to Mouse to Man,” Ph.D. dissertation, Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis.
Manduca, A., Lake, D. S., Kruse, S. A., and Ehman, R. L., 2003, “Spatio-Temporal Directional Filtering for Improved Inversion of MR Elastography Images,” Med. Image Anal., 7(4), pp. 465–73. [CrossRef] [PubMed]
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., Fink, M., 2005, “Imaging Anisotropic and Viscous Properties of Breast Tissue by Magnetic Resonance Elastography,” Magn. Reson. Med., 53(2), pp. 372–387. [CrossRef] [PubMed]
Romano, A. J., Scheel, M., Hirsch, S., Braun, J., and Sack, I., 2012, “In Vivo Waveguide Elastography of White Matter Tracts in the Human Brain,” Magn. Reson. Med. (epub ahead of print).
Spencer, A. J. M., 1984, Continuum Theory of the Mechanics of Fibre-Reinforced Composites, Springer-Verlag, Berlin.

Figures

Grahic Jump Location
Fig. 1

A time history of the axial displacement field produced by the closed-form analytical solution. The field is shown through a series of eight phase offsets (φ1,φ2,...,φ8) over one complete cycle. Outwardly propagating shear waves are excited by the axial vibration of a central filament. In addition to the Bessel function solution, a harmonic axial rigid body displacement was added. Parameters: G' = 1.2 kPa, G″ = 0.18 kPa, density ρ = 1100 kg/m3, frequency f = 400 Hz, and cylinder radius R = 22.5 mm.

Grahic Jump Location
Fig. 2

(a) Transversely isotropic material model with the axis of symmetry (fiber axis) aligned with the x1-axis. (b)-(d) Application of shear stress along a face produces a corresponding shear strain in proportion to the shear modulus. In transversely isotropic media there are two shear moduli: μT describes shear in a plane normal to the symmetry axis, and μL in planes parallel to the symmetry axis. Biological media often exhibit μL>μT (γij = 2εij, for i≠j). Reproduced from Ref. [26].

Grahic Jump Location
Fig. 5

Comparison of the viscoelastic distortion-based LFE inversion (red dots) with total least-squares (TLS) direct inversion (black lines) performed by Okamoto [20]. Results in this study were not corrected for test-order temperature variations as they were in the Okamoto study (dashed black lines). Error bars represent ± 1 std. dev.

Grahic Jump Location
Fig. 4

Homogeneous isotropic viscoelastic inversion validation in the presence of rigid body (zero strain) motion. Storage G' and loss G" moduli are shown for inversion of the (a) distortion field Γ (G' = 1.32 ± 0.37 kPa; G″ = 0.21 ± 0.09 kPa), and (b) displacement field (G' = 7.48 ± 7.78 kPa; G″ = 5.55 ± 9.89 kPa). (Gtrue' = 1.2 kPa; Gtrue″ = 0.18 kPa.)

Grahic Jump Location
Fig. 3

Axial displacement fields from finite element simulations. (a) Fiber orientation aligned with the x1-axis. (b) Outwardly propagating shear waves excited by the axial vibration of a central filament. (c) Inwardly-propagating waves excited by the axial vibration of the outer boundary. Parameters: shear moduli μL = 2000 Pa, μT = 1000 Pa, density ρ = 1000 kg/m3, frequency f = 5 Hz, and cylinder radius R = 1 m. The loss factor (η = G″/G') of the material is 0.20.

Grahic Jump Location
Fig. 6

(a) Estimates of shear modulus assuming an isotropic material model. (b) Estimates of shear modulus μL (mean ± std. dev. = 1761 ± 111 Pa) obtained using the LFE-based approach for transversely isotropic materials. (c) Estimates of shear modulus μT (1045 ± 152 Pa). The true values are μL = 2000 and μT = 1000. In the anisotropic case, the estimation error increases in regions where the shear wave does not sufficiently activate a plane of shear governed by either μL or μT.

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In