0
RESEARCH PAPERS

Biomechanical Properties of Human Cadaveric Ankle-Subtalar Joints in Quasi-Static Loading

[+] Author and Article Information
C. S. Parenteau

Department of Injury Prevention, Chalmers University of Technology, 412 96 Gothenberg, Sweden

D. C. Viano

Department of Injury Prevention, Chalmers University of Technology, 412 96 Gothenberg, Sweden; Research & Development Center, General Motors Corporation, Warren, MI 48090-9055

P. Y. Petit

Ecole Nationale Supérieure d’Arts et Métiers, 151 Boulevard de I’Hôpital, 75013 Paris, France

J Biomech Eng 120(1), 105-111 (Feb 01, 1998) (7 pages) doi:10.1115/1.2834289 History: Received March 26, 1996; Revised January 09, 1997; Online January 07, 2008

Abstract

The biomechanical properties of human ankle-subtalar joints have been determined in a quasi-static loading condition. The moving center of rotation was determined and approximated by a fixed point. The moment-angle characteristics of the ankle-subtalar joints about the fixed center of rotation have been measured under four basic movements: dorsiflexion, plantarflexion, inversion, and eversion. The method linearly increases rotation of the calcaneus until failure, and measures the moments, forces, and linear and rotational displacements. Failure was identified as the initial drop of moment on plot showing the moment representing gross injury or microfilament damage. In this study, 32 human ankle-subtalar joints have been tested to failure. The center of rotation of the ankle-subtalar joints was determined for a pure dorsiflexion (9 specimens), plantarflexion (7 specimens), inversion (8 specimens), and eversion (8 specimens), Failure in the joints occurred at an average moment of −33.1 ± 16.5 Nm in dorsiflexion, 40.1 ± 9.2 Nm in plantarflexion, −34.1 ± 14.5 Nm in inversion, and 48.1 ± 12.2 Nm in eversion. The failure angle was also determined in all four motions. Failure was best predicted by an angle of −44.0 ± 10.9 deg in dorsiflexion, 71.6 ± 5.7 deg in plantarflexion, −34.3 ± 7.5 deg in inversion, and 32.4 ± 7.3 deg in eversion. Injury was identified in every preparation tested in inversion and eversion, while it resulted in five of the nine preparations in dorsiflexion, and in three of the seven in plantarflexion. Injury occurred at −47.0 ± 5.3 deg and −36.2 ± 14.8 Nm in dorsiflexion, and at 68.7 ± 5.9 deg and 36.7 ± 2.5 Nm in plantarflexion. The results obtained in this study provide basic information of the ankle-subtalar joint kinematics, biomechanics, and injury. The data will be used to form a basis for corridors of the ankle-subtalar joint responses.

Copyright © 1998 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In