Ultrasonic Wave Velocity Measurement in Small Polymeric and Cortical Bone Specimens

[+] Author and Article Information
S. S. Kohles, R. Vanderby

Division of Orthopedic Surgery and Department of Mechanical Engineering. University of Wisconsin, Madison, WI 53792

J. R. Bowers

Division of Orthopedic Surgery and Department of Electrical Engineering. University of Wisconsin, Madison, WI 53792

A. C. Vailas

Division of Orthopedic Surgery and Department of Kinesiology. University of Wisconsin, Madison, WI 53792

J Biomech Eng 119(3), 232-236 (Aug 01, 1997) (5 pages) doi:10.1115/1.2796085 History: Received August 10, 1995; Revised September 03, 1996; Online October 30, 2007

Abstract

A system was refined for the determination of the bulk ultrasonic wave propagation velocity in small cortical bone specimens. Longitudinal and shear wave propagations were measured using ceramic, piezoelectric 20 and 5 MHz transducers, respectively. Results of the pulse transmission technique were refined via the measurement of the system delay time. The precision and accuracy of the system were quantified using small specimens of polyoxymethylene, polystyrene-butadiene, and high-density polyethylene. These polymeric materials had known acoustic properties, similarity of propagation velocities to cortical bone, and minimal sample inhomogeneity. Dependence of longitudinal and transverse specimen dimensions upon propagation times was quantified. To confirm the consistency of longitudinal wave propagation in small cortical bone specimens (<1.0 mm), cut-down specimens were prepared from a normal rat femur. Finally, cortical samples were prepared from each of ten normal rat femora, and Young’s moduli (Eii ), shear moduli (Gij ), and Poisson ratios (vij ) were measured. For all specimens (bone, polyoxymethylene, polystyrene-butadiene, and high-density polyethylene), strong linear correlations (R2 > 0.997) were maintained between propagation time and distance throughout the size ranges down to less than 0.4 mm. Results for polyoxymethylene, polystyrene-butadiene, and high-density polyethylene were accurate to within 5 percent of reported literature values. Measurement repeatability (precision) improved with an increase in the wave transmission distance (propagating dimension). No statistically significant effect due to the transverse dimension was detected.

Copyright © 1997 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In