Fluid Dynamics of a Partially Collapsible Stenosis in a Flow Model of the Coronary Circulation

[+] Author and Article Information
Maria Siebes

Department of Biomedical Engineering, The University of Iowa, Iowa City, IA 52242

Charles S. Campbell

Department of Mechanical Engineering

David Z. D’Argenio

Department of Biomedical Engineering. University of Southern California, Los Angeles, CA 90089-1451

J Biomech Eng 118(4), 489-497 (Nov 01, 1996) (9 pages) doi:10.1115/1.2796035 History: Received July 14, 1992; Revised November 05, 1995; Online October 30, 2007

Abstract

The influence of passive vasomotion on the pressure drop-flow (ΔP-Q) characteristics of a partially compliant stenosis was studied in an in vitro model of the coronary circulation. Twelve stenosis models of different severities (50 to 90 percent area reduction) and degrees of flexible wall (0 to 1/2 of the wall circumference) were inserted into thin-walled latex tubing and pressure and flow data were collected during simulated cardiac cycles. In general, the pressure drop increased with increasing fraction of flexible wall for a given flow rate and stenosis severity. The magnitude of this effect was directly dependent upon the underlying stenosis severity. The diastolic ΔP-Q relationship of severe, compliant models exhibited features of partial collapse with an increase in pressure drop at a decreasing flow rate. It is concluded that passive vasomotion of a normal wall segment at an eccentric stenosis in response to periodic changes in intraluminal pressure causes dimensional changes in the residual lumen area which can strongly affect the hemodynamic characteristics of the stenosis during the cardiac cycle. This mechanism may have important implications for the onset of plaque fracture and the prediction of the functional significance of a coronary stenosis based on quantitative angiogram analysis.

Copyright © 1996 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In