Flow Measurements in an Aortocoronary Bypass Graft Casting

[+] Author and Article Information
E. Y. Kwack, L. H. Back

Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109

X. M. Ruan, A. Chaux

Department of Thoracic and Cardiovascular Surgery, Cedars Sinai Medical Center, Los Angeles, CA 90048

J Biomech Eng 118(2), 165-171 (May 01, 1996) (7 pages) doi:10.1115/1.2795955 History: Received March 04, 1994; Revised April 20, 1995; Online October 30, 2007

Abstract

Flow visualization and pressure measurements were carried out in a single valve saphenous vein casting which was made from a saphenous vein segment obtained from a bypass patient at Cedars Sinai Medical Center. Dye was injected to understand the flow around the valve. The dye showed very complex flow patterns around the valve and in the valve sinus, and the cavity formed by a ligated branch. For steady flow, pressure drops across the valve were 0.72, 2.0 and 6.3 mmHg for the physiological flow rates of 45, 84, and 169 ml/min, respectively. Overall pressure drop across the casting (compared to Poiseuille flow for a straight tube) increased with the flow rate, being 130 to 290 percent higher over this flow rate range. In the case of pulsatile flow, pressure drops across the valve were 0.95 and 3.0 mmHg for the flow rates of 47 and 87 ml/min which were 26 and 43 percent higher than those of steady flow. Overall pressure drop was 220 and 360 percent higher for those flow rates compared to Poiseuille flow. The measured spatial pressure distributions along the casting and flow visualization indicated the global nature of the flow field with the accelerated flow through the valve separating and reattaching downstream along the wall in the pressure recovery region. Atherosclerosis may be prone to occur in the lower shear region along the wall beyond the valve tip in the reattachment region, as we have observed in vivo in rabbit experiments.

Copyright © 1996 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In