0
TECHNICAL PAPERS

A New Device and Method for Controlling the Load in Rabbit Medial Collateral Ligament Reconstructions

[+] Author and Article Information
G. J. W. King, E. L. Damson, C. B. Frank, N. G. Shrive

Joint Injury and Arthritis Research Group, University of Calgary, Calgary, Alberta, Canada

J Biomech Eng 117(1), 41-47 (Feb 01, 1995) (7 pages) doi:10.1115/1.2792268 History: Received May 12, 1992; Revised April 04, 1994; Online October 30, 2007

Abstract

In order to study the effect of intra-operative tensioning on the laxity and strength of healing ligament grafts in an animal model, a method of quantifying graft tension was needed. In this study a sensitive ligament tensioning device was developed to measure accurately the prefixation loads in the rabbit medial collateral ligament (MCL) graft. To verify that reproducible changes in ligament tension could be created with the tensioning device, a group of animals had their MCL grafts replaced at one of three different graft loads (tight, anatomic, or loose). The tensioning device consists of two posts which move relative to one another by means of an axial screw. The movable post, which is inserted into the tibial bone island of the MCL graft has a series of strain gauges which can measure the tension applied to the graft. The stationary post attaches to the tibial shaft, permitting the ligament graft to be tensioned relative to this fixed point. After graft tensioning and fixation, the animals were euthanized immediately postoperatively and their ligament load-deformation behavior was measured using an Instron materials testing machine. Specific measures of low load behavior was taken to quantify ligament laxity. Our results demonstrate that the tensioning device was capable of reproducibly altering prefixation graft load intra-operatively as well as MCL laxity immediately postoperatively. A baseline of laxity values was thus developed to follow changes in this laxity measure for future studies of MCL graft healing in this model.

Copyright © 1995 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In