0
TECHNICAL PAPERS

Direct In Vitro Determination of the Patellofemoral Contact Force for Normal Knees

[+] Author and Article Information
R. Singerman, J. Berilla, D. T. Davy

Orthopaedic Engineering Laboratory, Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106

J Biomech Eng 117(1), 8-14 (Feb 01, 1995) (7 pages) doi:10.1115/1.2792275 History: Received March 30, 1993; Revised January 25, 1994; Online October 30, 2007

Abstract

Results of the direct in vitro measurement of the full three-dimensional representation of the patellofemoral contact force and the point of application on the patella of the resultant contact force for eleven normal knees are presented. The applied knee moment versus flexion angle pattern was similar to that experienced when rising from a chair. There was a wide variability of the details of the patellofemoral force interaction among the specimens tested. The magnitude of the resultant contact force increased approximately linearly with flexion angle for some knees while in others the force leveled off or decreased at higher flexion angles. The change in direction of the resultant contact force with respect to the patella was relatively small compared to the angular rotation of the patella. The medial-lateral component of the contact force exhibited substantial variability among knees. The direction of this force (medially or laterally directed) varied among knees and, in some knees, changed direction as a function of flexion angle. The point of application on the patella of the resultant contact force migrated superiorly from 20 to 90 deg flexion. Above 90 deg flexion this point tended to migrate inferiorly. The only significant and consistent effect of varying the direction of the quadriceps extension force was a change in the medial-lateral component of the contact force. In all cases, the tendency to sublux laterally increased when the extensor force was rotated 10 deg laterally and decreased when the extensor force was rotated 10 deg medially.

Copyright © 1995 by The American Society of Mechanical Engineers
Topics: Force , Knee , Rotation
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In