Shear Stress at a Compliant Model of the Human Carotid Bifurcation

[+] Author and Article Information
A. S. Anayiotos

Department of Mechanical Engineering, University of Alabama at Birmingham, Birmingham, AL 35242-4461

S. A. Jones, D. P. Giddens

School of Engineering, The Johns Hopkins University, Baltimore, MD 21218

S. Glagov, C. K. Zarins

Department of Pathology and Surgery, The University of Chicago, School of Medicine, Chicago, IL 60637

J Biomech Eng 116(1), 98-106 (Feb 01, 1994) (9 pages) doi:10.1115/1.2895710 History: Received April 30, 1991; Revised March 29, 1993; Online March 17, 2008

Abstract

To investigate the role of a compliant wall to the near wall hemodynamic flowfield, two models of the carotid bifurcation were constructed. Both were of identical internal geometries, however, one was made of compliant material which produced approximately the same degree of wall motion as that occurring in vivo while the other one was rigid. The inner geometries were formed from the same mold so that the configurations are directly comparable. Each model was placed in a pulsatile flow system that produced a physiologic flow waveform. Velocity was measured with a single component Laser system and wall shear rate was estimated from near wall data. Wall motion in the compliant model was measured by a wall motion transducer and the maximum diameter change varied between 4-7 percent in the model with the greatest change at the axis intersection. The mean shear stress in the compliant model was observed to be smaller by about 30 percent at most locations. The variation in peak shear stress was greater and occasionally reached as much as 100 percent with the compliant model consistently having smaller positive and negative peaks. The separation point was seen to move further upstream in the compliant cast. The modified flowfield in the presence of a compliant wall can then be important in the hemodynamic theory of atherogenesis.

Copyright © 1994 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In