Theoretical Analysis of the Large Blood Vessel Influence on the Local Tissue Temperature Decay After Pulse Heating

[+] Author and Article Information
L. X. Xu

Department of Applied Sciences, The College of Staten Island/CUNY, Staten Island, NY 10301

M. M. Chen

Department of Mechanical and Industrial Engineering, University of Illinois, Urbana, IL 61801

K. R. Holmes

Department of Veterinary Biosciences, University of Illinois, Urbana, IL 61801

H. Arkin

The National Institute for Building Research, Technion, Haifa 32000, Israel

J Biomech Eng 115(2), 175-179 (May 01, 1993) (5 pages) doi:10.1115/1.2894118 History: Received August 15, 1991; Revised June 15, 1992; Online March 17, 2008

Abstract

The influence of a large blood vessel (larger than 500 μm in diameter) on the local tissue temperature decay following a point source heating pulse was determined numerically using a sink/source method. It was assumed that the vessel was large enough so that the temperature of blood flowing within it remained essentially constant and was unaffected by any local tissue temperature transients. After the insertion of a point source heating pulse, the vessel influence on the local tissue transient temperature field was estimated by representing the vessel as a set of negative fictitious instantaneous heat sources with strength just sufficient to maintain the vessel at a constant temperature. In the surrounding tissue, the Pennes’ tissue heat transfer equation was used to describe the temperature field. Computations have been performed for a range of vessel sizes, probe-vessel spacings and local blood perfusion rates. It was found that the influence of a large vessel on the local tissue temperature decay is more sensitive to its size and location rather than to the local blood perfusion rate. For a heating pulse of 3s duration and 5 mW of power, there is a critical probe-vessel center distance 7R (R, vessel radius) beyond which the larger vessel influence on tissue temperature at the probe can be neglected.

Copyright © 1993 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In