Abstract

The use of a perforated, titanium funicular shell to support the proximal femoral cortex in total hip arthroplasty was evaluated with the aid of both analytical and numerical techniques. The principal interactions between the femoral cortex, the metal shell, the implant stem and the acrylic bone cement were modeled using beam on elastic foundations theory and two-dimensional elasticity theory. Subsequent formulation of this model as a nonlinear design optimization problem enabled the determination of the dimensions of the implant and reinforcing shell which minimized an objective function based on a simplified material failure criterion. Two cases were examined, each with two cervico-diaphyseal angles: case A: with a rigid contact between a proximal prosthesis collar and the calcar femorale and case B: no collar contact (a collarless prosthesis or post-operative loosening). Case A achieved an optimal solution at a stem diameter 11–23 percent of the cortex inner diameter, a stem length to diameter ratio of 12–40, shell diameter 22–53 percent and thickness 0.2–7.2 percent of the cortex inner diameter and thickness, respectively. Case B achieved an optimal solution at a stem diameter 67–92 percent of the cortex inner diameter, length to diameter ratio of 4–6, and no shell. In case A the collar support makes the type of internal fixation unimportant, while in the more realistic case B, the shell is not recommended.

Copyright © 1990 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In