0
RESEARCH PAPERS

An Experimental Study of Newtonian and Non-Newtonian Flow Dynamics in a Ventricular Assist Device

[+] Author and Article Information
K. A. Mann, D. B. Geselowitz

Department of Bioengineering, The Pennsylvania State University, University Park, PA 16802

S. Deutsch

Applied Research Laboratory, The Pennsylvania State University, University Park, PA 16802

J. M. Tarbell

Department of Chemical Engineering, The Pennsylvania State University, University Park, PA 16802

G. Rosenberg, W. S. Pierce

School of Medicine, The Pennsylvania State University, University Park, PA 16802

J Biomech Eng 109(2), 139-147 (May 01, 1987) (9 pages) doi:10.1115/1.3138656 History: Received April 16, 1986; Revised January 05, 1987; Online June 12, 2009

Abstract

The fluid dynamic behavior of a Newtonian water/glycerol solution, a non-Newtonian polymer (separan) solution, and bovine blood were compared in the Penn State Electrical Ventricular Assist Device (EVAD). Pulsed doppler ultrasound velocimetry was used to measure velocities in the near wall region (0.95–2.7 mm) along the perimeter of the pump. Mean velocity, turbulence intensity, local and convective acceleration, and shear rate were calculated from the PDU velocity measurements. Flow visualization provided qualitative information about the general flow patterns in the EVAD. Results indicate that water/glycerol does not accurately model the flow characteristics of bovine blood in the EVAD. The non-Newtonian separan solution produced results closer to those of the bovine blood than did the water/glycerol solution. Near wall velocity magnitudes for the separan were similar to those of the bovine blood, but the profile shapes differed for portions of the pump cycle. All three fluids exhibited periods of stagnation. Bovine blood results indicated the presence of a desired rotational washout pattern at mid-systole, while results with the other fluids did not show this feature.

Copyright © 1987 by ASME
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In